Vortex Flow Meter “Maxiflo”

 

Measured Media: Liquid, Gas, Steam

Velocity Range
     Liquid: 0.4 ~ 7 m/s
     Gas: 4 ~ 60 Nm/s
     Steam: 5 ~ 70 Nm/s

Pipe Sizes
     Inline Type: DN25 ~ DN300 mm (1″ ~ 12″)
     Insertion Type: DN100 ~ DN3000 mm (4″ ~ 120″)

Max. Pressure: Equal to the pipe pressure rating

Max. Temp.: -40℃ ~ +250℃ (+350℃ for remote type)

Material of the Sensor: Stainless Steel

Indicator/Transmitter
     Vortex Sensing: by Strain Gauge
     Display: Flow Rate, Total, Freq., Density, Temp., etc.
     Output: 4-20mA+HART, Pulse, RS-485 (MODBUS-RTU)
     Power: 24VDC/Battery (3.6V)
     Material: Die-cast AluminumTemperature Sensor: RTD, PT-100Ω/PT-1000ΩPressure Sensor: PZT

Accuracy
     Liquid: ±1.0%, FS
     Gas/Steam: ±1.0%, FS

Enclosure: IP65, Ex-Proof (Exia IIC T6, optional)